transactions supported

 Home | Electronic ignitions | Business conditions | Worldwide delivery | Contacts   

IMFsoft
Master Ignition CDI 7 – 36V
120.000RPM
Direct Ignition TCI 3,5 - 25V
25.000RPM
USB 2.0
Universal Ignition 3,5 - 25V
25.000RPM
RS232
Accessories Sensors
Connectors
Coils

Master ignition

Master Ignition Control application

Online visualisation

This is an operational display of function and status of ignition unit MASTER. In order to have functional display it is necessary to have USB connection and switch power supply on.

Visualised data:

Oscilloscopic record

Oscilloscopic record is used in order to graphically visualise measured and calculated data. This helps to quickly evaluate the proper and accurate function of ignition unit MASTER. It can thus evaluate the correctness of voltage sensing, counting teeth of mathematic model of the real rotation and angels of closing of output coils.

An example to be given; curve angle of engine displacement must be regularly and horizontally increased from 0 to 360°. If there is any change of steepness in the curve or the angle is shorten, the problem is to be found either in wrong angle set up, number of teeth, the type of synchronisation or unsuitable voltage for sensing.

Visualised data:

In this example, red colour refers to progress of voltage of sensor PA type HALL and INDUCTIVE, which scans three teeth 0-90-180° and in angle 270° 1OA output is switched – grey curve. Blue colour represents teeth counting and the last curve refers to spinning of engine within the range of 0-360°.

Maps of advance

Maps provide a fast tool to display and model individual curves in advance [1] – [8] in full angle range ±360°. The given figure influences the moment of output switch from 1OA to 1OH. By using digital (DI1, DI2) or analogue outputs AI1, AI2, PA, PB) it is possible to operationally switch among the maps.

Modelling tools:



Price from 279 EUR

Buy now!



transactions supported
© 2006 – 2012 IMFsoft, Ltd.